Water heaters »
Products »
Combined heaters »
Suspended, vertical
Suspended, vertical
Summary
| Suspended, vertical – heat exchanger 0.41 m2 | Suspended, vertical – heat exchanger 0.7 m2 | Suspended, vertical – heat exchanger 1 m2 |
| OKC 80 |
OKC 100, OKC 125, OKC 160, OKC 180, OKC 200 |
OKC 100/1 m2, OKC 125/1 m2, OKC 160/1 m2, OKC 180/1 m2, OKC 200/1 m2 |
Character
- Operating position – vertical (suspended on the wall)
- Combined storage water heaters designed for suspension on the wall with volumes of 80–200 litres. The manufacturer throughout all the history of the heaters production keeps same pitch of the anchoring bolts in order to assure easy replacement of time-expired water heaters. It is also possible to buy the suspension for the pitch of the anchoring bolts reaching 350 mm.
- Heating options
- Electric power. Ceramic heating element controlled by the operating thermostat and secured by the safety thermostat (thermal fuse).The thermal range is 5–74 °C. Connection voltage is 1-PE–N/AC 230 V/50 Hz. The IP 45 electric shielding enables mounting of heaters above baths.
- Heat exchanger. The heater may be connected to an external hot water source with the max. temperature of 110 °C and pressure of 1 MPa . Heater with the adequate output of the heat exchanger must be linked depending on the output of the source. The heat exchanger works in forced circulation mode and also in self-circulation system. The heating water regulation sensor may be inserted into the common receiver with electric installation sensors.
- Most common use
- Preparation of hot utility water for premisses with hot water central heating using gas and solid fuels during a winter season.
- Electric heating off the heating period is enabled with the possibility to use the low tariff of electric supply (night tariff).
- Accessories
- Safety valve
- Optional equipment
- Circulation input
- Two and three-phase connection 400 V/50 Hz
- The heating element with higher power output, max. 4 kW
Cut
Technical data
| Type | OKC 80 | OKC 100 | OKC 125 | OKC 160 | OKC 180 | OKC 200 |
| Volume [l] |
75 |
95 |
120 |
147 |
175 |
195 |
| Nominal overpressure [MPa] |
0,6 |
0,6 |
0,6 |
0,6 |
0,6 |
0,6 |
| Voltage [V] |
230 |
230 |
230 |
230 |
230 |
230 |
| Power input [W] |
2 000 |
2 000 |
2 000 |
2 000 |
2 200 |
2 200 |
| Electric protection category |
IP 45 |
IP 45 |
IP 45 |
IP 45 |
IP 45 |
IP 45 |
| Heater height [mm] |
736 |
881 |
1 046 |
1 235 |
1 200 |
1 300 |
| Heater diameter [mm] |
524 |
524 |
524 |
524 |
584 |
584 |
| Max. weight of the heater without water [kg] |
42 |
52 |
58 |
66 |
76 |
81 |
| Electrical heating rate from 10 °C to 60 °C [hod] |
2,5 |
3 |
3,8 |
5 |
5 |
5,5 |
| Max. operating overpressure [MPa] |
1 |
1 |
1 |
1 |
1 |
1 |
| Heat exchanger surface [m^^2^^] |
0,41 |
0,68 |
0,68 |
0,68 |
0,68 |
0,68 |
| Nominal heat output at heating water temperature of 80 °C and flow rate 310 l/h [W] |
7 000 |
9 000 |
9 000 |
9 000 |
9 000 |
9 000 |
| Heating unit rate from 10 °C to 60 °C [min] |
50 |
48 |
55 |
75 |
77 |
86 |
| Nominal heat output at heating water temperature of 80 °C and flow rate 720 l/h [W] |
9 000 |
17 000 |
17 000 |
17 000 |
17 000 |
17 000 |
| Heating unit rate from 10 °C to 60 °C [min] |
32 |
23 |
28 |
35 |
40 |
45 |
| Heat loss/energy efficiency category [kWh/24 hod] |
0,71/C |
0,88/C |
1,09/C |
1,39/C |
1,39/B |
1,4/B |
| Type | OKC 100/1 m2 | OKC 125/1 m2 | OKC 160/1 m2 | OKC 180/1 m2 | OKC 200/1 m2 |
| Volume [l] |
95 |
120 |
160 |
180 |
200 |
| Maximal heating unit overpressure [MPa] |
0,6 |
0,6 |
0,6 |
0,6 |
0,6 |
| Voltage [V] |
230 |
230 |
230 |
230 |
230 |
| Power input [W] |
2 000 |
2 000 |
2 000 |
2 200 |
2 200 |
| Electric protection category |
IP 45 |
IP 45 |
IP 45 |
IP 45 |
IP 45 |
| Heater height [mm] |
881 |
1 046 |
1 235 |
1 200 |
1 300 |
| Heater diameter [mm] |
524 |
524 |
524 |
584 |
584 |
| Max. weight of the heater without water [kg] |
58 |
64 |
72 |
82 |
88 |
| Electrical heating rate from 10 °C to 60 °C [hod] |
3 |
3,8 |
5 |
5 |
5,5 |
| Max. operating overpressure [MPa] |
1 |
1 |
1 |
1 |
1 |
| Heat exchanger surface [m^^2^^] |
1,08 |
1,08 |
1,08 |
1,08 |
1,08 |
| Nominal heat output at heating water temperature of 80 °C and flow rate 720 l/hod [W] |
24 000 |
24 000 |
24 000 |
24 000 |
24 000 |
| Heating unit rate from 10 °C to 60 °C [min] |
14 |
17 |
23 |
26 |
28 |
| Heat loss/energy efficiency category [kWh/24 hod] |
0,88/C |
1,09/C |
1,39/C |
1,39/B |
1,4/B |
Download
Actual page from our catalogue (PDF .) – assembly scheme etc. You can download Operational manuals also.