Water heaters » Products » Indirect heaters » Stationary 0.6 MPa » Outlet on the side

Outlet on the side

Summary

Stationary 0.6 MPa – outlet on the side of the exchanger, without side flange
OKC 100 NTR, OKC 125 NTR, OKC 160 NTR, OKC 200 NTR, OKC 250 NTR, OKC 200 NTRR, OKC 250 NTRR, OKH 100 NTR, OKH 125 NTR, OKH 160 NTR

Character

OKC – Rounded

OKH – Square

Heater design

Indirect water heaters designed for placing on the floor with volumes between 100–250 litres with enamelled vessel and powerful heat exchanger used for heating of hot utility water from external sources. Heaters with volumes 200 and 250 litres are produced in versions with two heat exchangers used for connection from two heating water sources (e.g. gas boiler + alternative source) . By connecting of both heat exchangers in series the user may get hot water source with the output up to 44 kW. The heater is equiped with hot water heating temperature regulation system (thermostat controlling the three-way valve or circulation pump) for the voltage 230 V/50 Hz, safety valve and circulation outlet.

Most common use

All-year heating of hot utility water using heating water from the gas boiler with connection with the priority of hot water heating. In the OKC x NTRR type the gas boiler may be combined with an alternative heat source or by connecting both heat exchangers into series will become indirect heating reservoir for the boilers with the capacity above 24 kW.

Cut

OKC 200 NTR

OKC 200 NTRR

Technical data

TypeOKC 100 NTROKC 125 NTROKC 160 NTROKC 200 NTROKC 250 NTR
Volume [l] 95 115 145 210 250
Weight [kg] 57 69 77 95 107
Heater height [mm] 881 1 046 1 235 1 330 1 508
Heater diameter [mm] 524 524 524 584 584
Heat exchanger surface [m2] 1,08 1,45 1,45 1,45 1,45
Vessel max. pressure [MPa] 0,6 0,6 0,6 0,6 0,6
Exchanger max. pressure [MPa] 1 1 1 1 1
HUW . inlet JS 3/4" JS 3/4" JS 3/4" JS 3/4" JS 3/4"
Heating water inlet JS 1" JS 1" JS 1" JS 1" JS 1"
Operating temperature range [°C] to 80 to 80 to 80 to 80 to 80
Recommended HUW . temperature 60 60 60 60 60
Connection voltage 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz
Nominal heat output at heating water temperat. of 80 °C and flow rate 720 l/hod [W] 24 000 32 000 32 000 32 000 32 000
Heating rate from 10 °C to 60 °C [min] 14 17 23 28 36
Electric protection category IP 44 IP 44 IP 44 IP 44 IP 44
Heat loss [kWh/24 hod] 0,9 1,1 1,39 1,4 1,73

HUW – heat utility water.

TypeOKC 200 NTRROKC 250 NTRR
Volume [l] 200 245
Weight [kg] 108 118
Heater height [mm] 1 330 1 508
Heater diameter [mm] 584 584
Heat exchanger surface [m2] 1× 2 1× 2
Vessel max. pressure [MPa] 0,6 0,6
Exchanger max. pressure [MPa] 1 1
HUW . inlet JS 3/4" JS 3/4"
Heating water inlet JS 1" JS 1"
Operating temperature range [°C] to 80 to 80
Recommended HUW . temperature [°C] 60 60
Connection voltage 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz
Nominal heat output at heating water temperat. of 80 °C and flow rate 720 l/hod [W] 2× 24 000 2× 24 000
Heating rate from 10 °C to 60 °C [min] 28/16 36/20
Electric protection category IP 44 IP 44
Heat loss [kWh/24 hod] 1,4 1,73

HUW – heat utility water.

TypeOKH 100 NTROKH 125 NTROKH 160 NTR
Volume [l] 95 115 145
Weight [kg] 57 69 77
Heater height [mm] 881 1 046 1 235
Heater width x depth [mm] 520×520 520×520 520×520
Heat exchanger surface [m2] 1,08 1,45 1,45
Vessel max. pressure [MPa] 0,6 0,6 0,6
Exchanger max. pressure [MPa] 1 1 1
HUW . inlet JS 3/4" JS 3/4" JS 3/4"
Heating water inlet JS 1" JS 1" JS 1"
Operating temperature range [°C] to 80 to 80 to 80
Recommended HUW . temperature 60 60 60
Connection voltage 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz 1 P-EN AC 230 V/50 Hz
Nominal heat output at heating water temperat. of 80 °C and flow rate 720 l/hod [W] 24 000 32 000 32 000
Heating rate from 10 °C to 60 °C [min] 14 17 23
Electric protection category IP 44 IP 44 IP 44
Heat loss [kWh/24 hod] 0,7 0,87 1,05

Download