Water heaters » Products » Indirect heaters » Stationary 0.6 MPa » With side flange

With side flange

Summary

Stationary 0.6 MPa – with side flange
OKC 100 NTR/BP, OKC 125 NTR/BP, OKC 160 NTR/BP, OKC 200 NTR/BP, OKC 250 NTR/BP, OKC 300 NTR/BP, OKC 200 NTRR/BP, OKC 250 NTRR/BP, OKC 300 NTRR/BP

Character

BP design – side flange
Newer series of enamelled indirect heaters designed for placing on the floor with volumes between 100–300 litres with enamelled vessel and one or two (beginning from the 200 l types) high performance heat exchangers for heating of hot utility water from external sources or combination of different sources. By connecting of both heat exchangers in series the user may get hot utility water source with the output up to 57 kW. The heater is equipped with hot utility water temperature regulation system (thermostat controlling the three-way valve or circulation pump) for the voltage 230 V/50 Hz and up to volumes 200 l with a safety valve and circulation outlet.
In the lower part of the heater is a flange manhole used for cleaning the inside of the vessel and eventual insertion of the auxilliary electric heating of the TPK series from the accessories section. For the use of heaters for the solar system the heaters with the volume above 200 litres are equipped with a 6/4" neck located above the solar exchanger for the electric heating unit TJ from the accessories section.
Most common use
All-year heating of hot utility water using heating water from the gas boiler with connection with the priority of hot water heating. In the OKC x NTRR type the gas boiler may be combined with an alternative heat source or by connecting both heat exchangers into series will become indirect heating reservoir for the boilers with the capacity above 24 kW.

Cut

OKC 100 NTR/BP

OKC 200 NTR/BP

OKC 200 NTRR/BP

Technical data

TypeOKC 100 NTR/BPOKC 125 NTR/BPOKC 160 NTR/BPOKC 200 NTR/BPOKC 250 NTR/BPOKC 300 NTR/BP
Volume [l] 95 120 155 210 250 300
Weight [kg] 59 72 82 97 106 111
Heater height [mm] 815 980 1 018 1 328 1 508 1 597
Heater diameter [mm] 524 524 584 584 584 670
Vessel operating pressure [MPa] 0,6 0,6 0,6 0,6 0,6 0,6
Heating water operating pressure [MPa] 1 1 1 1 1 1
Heating water max. temperature [°C] 110 110 110 110 110 110
HUW . max. temperature [°C] 80 80 80 80 80 80
Bottom exchanger heating surface [m2] 1,08 1,45 1,45 1,45 1,45 1,5
Bottom/top exchanger (BE/TE) output [kW] 24 32 32 32 32 35
Continuous HUW .* output BE ./TE . [l/hod] 610 990 990 990 990 1 100
Heating rate from 10 °C to 60 °C (by exchanger) [min] 14 14 17 22 28 24
Electrical heating rate from 10 °C to 60 °C (2,2 kW) [hod] 3 3,5 4,5 5,5 7 8,5
Electrical heating rate from 10 °C to 60 °C (3–6 kW) [hod] 6–3
Electric protection category IP 44 IP 44 IP 44 IP 44 IP 44 IP 44
Heat loss [kWh/24 hod] 0,9 1,05 1,39 1,4 1,72 1,86

HUW – heat utility water.

*) Hot utility water at 45 °C

TypeOKC 200 NTRR/BPOKC 250 NTRR/BPOKC 300 NTRR/BP
Volume [l] 195 245 295
Weight [kg] 111 118 127
Heater height [mm] 1 328 1508 1 597
Heater diameter [mm] 584 584 670
Vessel operating pressure [MPa] 0,6 0,6 0,6
Heating water operating pressure [MPa] 1 1 1
Heating water max. temperature [°C] 110 110 110
HUW . max. temperature [°C] 80 80 80
Bottom exchanger heating surface [m2] 1 1 1,5
Top exchanger heating surface [m2] 1 1 1
Bottom/top exchanger (BE/TE) output [kW] 2× 24 2× 24 35/27
Continuous HUW .* output BE ./TE . [l/hod] 670/650; 1 080** 670/650; 1 080** 1 100/760
Heating rate from 10 °C to 60 °C (by exchanger) [min] 28/16 36/20 24/16
Electrical heating rate from 10 °C to 60 °C (2,2 kW) [hod] 5,5 7 8,5
Electrical heating rate from 10 °C to 60 °C (3–6 kW) [hod] 6–3
Electric protection category IP 44 IP 44 IP 44
Heat loss [kWh/24 hod] 1,4 1,72 1,86

HUW – heat utility water.

*) Hot utility water at 45 °C; **) Exchangers connected in series

Download